Shunt active power filter thesis proposal useful device

Sangu Ravindra, Dr.V.C.Veera Reddy, Dr.S.Sivanagaraju. “Style of Shunt Active Power Filter to get rid of the harmonic currents and also to compensate the reactive power under distorted as well as imbalanced source voltages in steady condition”. Worldwide Journal of Engineering Trends and Technology (IJETT) ,V2(3):20-24 November to 12 , 2011. ISSN:2231-5381. world wide web.ijettjournal.org. Printed by Seventh Sense Research Group.

Abstract — The shunt active power filter has demonstrated to become a helpful device to get rid of harmonic currents and also to compensate react ive power for straight line/nonlinear loads. This paper presents a manuscript method of determine reference compensation currents from the 3 – phase shunt active power filter (APF) under distorted and/or imbalanced source voltages in steady condition. The suggested appro ach is in contrast to three reviewed shunt APF reference compensation strategies. Results acquired by simulations with Matlab and Simulink reveal that the suggested approach works better compared to reviewed approaches on paying reactive power and harm onic/neutral currents from the load, whether or not the source voltages are seriously distorted and imbalanced. Additionally, the suggested approach yields a less complicated style of the shunt APF controller.

[1] H. Akagi, Y. Kanazawa, A. Nabae,“Generalize Theory from the Immediate Reactive Power in 3 – Phase Circuits”. IPEC’83 – Int. Power Electronics Conf. Tokyo, japan, Japan, 1983, pp. 1375 1386.
[2] H. Akagi Y. Kanazawa, A. Nab “Instantaneous Reactive Power C ompensator Comprising Switching Devices without Energy Storage Components”, IEEE Trans. Industry Applic. vol. 20, May/June 1984.
[3] E. H. Watanabe, R. M. Stephan, M. Aredes, “New Concepts of Immediate Active and Reactive Forces in Electrical Syste ms with Generic Loads”, IEEE Trans.

Shunt active power filter thesis proposal Tokyo, Japan, 1983, pp

Power Delivery, vol. 8, no. 2, April 1993, pp. 697 – 703.
[4] M. Aredes, E. H. Watanabe, “New Control Algorithms for Series and Shunt 3 – Phase Four – Wire Active Power Filters”, IEEE Trans. Power Delivery, vol 10, no. 3, This summer 1995, pp. 1649 – 1656.
[5] J. L. Afonso, C. Couto, J. S. Martins, “Active Filters with Co ntrol In line with the p – q Theory”, IEEE Industrial Electronics Society E-newsletter, vol. 47, n 3, Set. 2000, pp. five to ten.
[6] J. L. Afonso, H. R. Silva, J. S. Martins, “Active Filters for P ower Quality Improvement”, IEEE Power Tech’2001, Porto, Portugal, 10 – 13 Set. 2001.
[7] Simulink – Model – Based and Sy stem – Based Design, Modelli ng, Simulation,Implementation version 5,The MathWorks, This summer 2002.
[8] IEEE Working Group on Nonsinusoidal Situations: Efects on Meter Performance and Definitions of Power, “Practical definitions for forces in systems with nonsinusoidal waveforms and unbalanced loads: attorney at law,” IEEE Trans. Power Delivery. vol. 11, no. 1, pp. 79 – 101, Jan. 1996.
[9] A. E. Emanuel, “Summary of IEEE Standard 1459: definitions for that measurement of electrical power quantities under sinusoidal, nonsinusoidal, balanced, or unbalanced conditions,” IEEE Trans. Ind. Appl. vol. 40, no. 3, pp. 8 69 – 876, May/Jun. 2004.

Keywords
Shunt active power filter, Current source convert ers, Straight line and nonlinear loads. PI Controllers .